Xantrex Trace SW Series II Inverters have been replaced with the new
Xantrex XW series of sine-wave inverters please click here to get to that page

Trace sinewave power inverters by Xantrex

 

 

 

Click on pix to view
The result of new ideas and technologies, the Trace SW Series II from Xantrex delivers sine wave power without compromise.  Now sine wave output with high efficiency, high surge ability and low idle current draw is available.  More than just the finest inverter, with three microprocessors and bi-directional power topology, it has features and capabilities that previously were non-existent or available only as separate products.

 

check our links below

Index and Home Page

 Site Map

Figuring Power Requirements

Load Evaluation Form

Insolation Map

Sample Systems

A.E. Component Overview

Component Pricing

Efficient Refrigeration

Propane Refrigeration

Conserv AC Refrigerator/Freezer

Generators: Wind, Gas, & Hydro

Solar Water Pumping

DC Sub Pump Info

Trace UX Series Specs

Trace DR Series Specs

Trace Sinewave Series

Solar Modules Specs

Air 403 Wind Generator

Ampair Wind Gen Specs

Aquair Hydro Gen Info

Solar Fencers & Ant Charmer

RV Systems

Who We Are/How To Order

Used & surplus bulletin board

Subscribe to our mailing list

Contact us

 

 

As an Inverter:
1)  Multiple step, low distortion, sine wave output with up to 96% peak conversion efficiency.  Very low idle current draw allows high efficiency even when powering small loads.
2)  Two inverters can be operated in series to provide 120/240 VAC three wire output with twice the power for 240 VAC loads.  Requires optional stacking interface cable.
3)  Adjustable search mode can reduce idle power draw to 1 watt when not operating AC loads.
4)  Adjustable low battery cutout voltage with adjustable time delay prevents damaging batteries.
5)  Protection circuitry guards against over-current, short circuit, over temperature, low battery and high battery conditions.  Includes islanding protection for utility connected applications.

As a Battery Charger:
1)  High efficiency, low current distortion design enables higher charge output from small generators.
2)  Three-stage, temperature compensated charging algorithm ensures maximum battery charging life.  Remote battery temperature probe is standard.  Includes manual equalize mode with adjustable settings.
3)  Adjustable grid and generator size allows matching of charger to the AC source.
4)  Automatic "back-off" system prevents overloading of generators or nuisance tripping of input breakers.

When connected to grid or generator, the SW Inverter synchronizes its waveform to that of the AC source, locks to it and operated in parallel.  This ability, coupled with the bi-directional power topology and micro-processor control, makes it possible for the unit to offer multiple operating modes.

Generator Support Mode:  When charging from a generator, the generator's output voltage and current are monitored.  If either falls outside user adjustable limits, the unit sheds itself as a load and then reverses the power flow if necessary.  This delivers energy from the batteries to the loads assisting the generator.  When operating two units in series at 240 VAC, one 120 VAC leg can be charging while the other is supporting.

Standby Power Mode:  Two AC inputs are provided--one for generator and one for utility grid.  When AC fails, transfer to inverter power is no longer than 34 milliseconds.  If the grid and generator are connected, the unit can be set to start the generator after the grid has failed. After grid returns, the generator is automatically stopped.  The inverter output is synchronized to the grid and the grid is reconnected to the loads.  Note:  generator must have the reciprocating circuitry to accommodate the SW inverter.

Battery Voltage and Transfer Mode:  If the batteries are low, a low battery set point triggers connection to the grid.

Generator Start Mode:  Automatic generator start features are standard and user programmable.  Gen start can be triggered by wither battery voltage or load size connected.  A "quiet time" can be set to restrict generator operation unless absolutely required.  The start sequence is fully adjustable and is now compatible with a greater variety of generator types.  Generator MUST be set up for remote starting and designed for unattended operation.

Utility Interactive Mode:  Operating as a bi-directional battery charger, power from any source that tries to raise the batteries above their programmed float voltage is delivered to the grid.  A GRID USAGE TIMER can be set to allow selling of electricity to the utility only during prescribed hours.  Sell back current is adjustable.  CAUTION:  Utility intertie must have approval of local utility company.

Peak Load Shaving Mode:  (1)  The sine wave series may be programmed to operate from batteries during a specified period of the day.  Batteries may be charged during lower rate periods.  (2)  During a programmable time of the day, power is delivered to the grid from the batteries.  An alternative (lower) adjustable float voltage is employed to allow variable battery discharge depths.

Three user adjustable voltage-controlled signal relays are provided to control charging sources and loads.

Selecting modes, enabling features and adjusting parameters are easily accomplished by moving through a menu tree that is displayed on the control panel's LCD read-out.  Doubling as a meter, the LCD displays inverter amps, input amps, load amps, battery volts DC and inverter volts AC.  Additionally, control panel LEDs report the status of eight system conditions.

We are proud to offer a full line of products from Xantrex formerly Trace Engineering
New Series II Design
1)  Easier to use programming system with separate "User" and "Setup" menus.
2)  New backlight LCD display on control panel improves use in low light conditions.
3)  Improved AC wiring access and AC conduit provisions makes installation easier.
4)  New "soft start" systems allows inverter to run even heavier loads and improves reliability.
5)  Includes a new, easier to read universal owners manual that covers all SW series II inverters.
6)  Enhanced generator start system works with a greater variety of generator types.

NOTE:  The above pricing reflectsTrace's list  pricing; if you buy your system from us you will receive substantial system discounts.  Call us for your Trace pricing!  (European voltage and hertz range also available).

 
Specifications SW2512 SW4024 SW3024E SW4048 SW3048E SW5548 SW4548E
Nominal DC Input Voltage
AC Output Voltage (RMS)
Nominal Frequency
Continuous Power @ 20°
Continuous AC Output (@ 25°C)
Maximum AC Output (RMS)
Efficiency (Peak)
Automatic AC Transfer Relay
Maximum Charging Rate
12VDC
120VAC
60 HZ
2500VA
21 amps
60 amps
90%
60 amps
150 amps
24VDC
120VAC
60 HZ
4000VA
33 amps
78 amps
94%
60 amps
120 amps
24VDC
230VAC
50 HZ
3300VA
14 amps
34 amps
94%
30 amps
100 amps
48VDC
120VAC
60 HZ
4000VA
33 amps
78 amps
95%
60 amps
60 amps
48VDC
230VAC
50 HZ
3300VA
14 amps
34 amps
95%
30 amps
50 amps
48VDC
120VAC
60 HZ
5500VA
46 amps
78 amps
96%
60 amps
75 amps
48VDC
230VAC
50 HZ
4500VA
20 amps
34 amps
96%
30 amps
60 amps
DC Input Requirements
Search Mode
On Mode (no load - idle)
At Full Rated Power
Short Circuited Output
Nominal DC Input Voltage Range

0.08A (1W)
1.0A (12W)
275 amps
700 amps
11.8 to 16.5

0.04A (1w)
0.66A (16W)
200 amps
360 amps
22 to 33

0.04A (1W)
0.66A (16W)
166 amps
320 amps
22 to 33

0.025A (1W)
0.33A (16W)
100 amps
180 amps
44 to 66

0.025A (1W)
0.33A (16W)
83 amps
160 amps
44 to 66

0.04A (1W)
0.40A (20W)
137 amps
180 amps
44 to 66

0.04A (1W)
0.40A (20W)
106 amps
138 amps
44 to 66
AC Output Characteristics
AC Output Waveform
Voltage Regulation
Total Harmonic Distortion
Power Factor Allowed
Frequency Regulation
Load Sensing Range

Sinewave, 34 to 52 steps per cycle
+/- 2%
3 to 5% (stand alone operation)
-1 to 1
+/- 0.04% (crystal regulated)
16 to 240 watts
Options
Remote Control Panel (50' max)
Stacking Interface for double power
  (required two inverters)
Conduit Box
DC Disconnect Breaker
DC Battery/Inverter Cables

SWRC
SWI
(120/240)
SWCB
DC 250
BC5-4/0

SWRC
SWI
(120/240)
SWCB
DC 250
BC5-4/0

SWRC
No

SWCB
DC 250
BC5-4/0

SWRC
SWI
(120/240)
SWCB
DC 175
BC5-2/0

SWRC
No

SWCB
DC 175
BC5-2/0

SWRC
SWI
(120/240)
SWCB
DC 250
BC5-4/0

SWRC
No

SWCB
DC 175
BC5-2/0
Enclosure Type
Specified Temp Range
Allowed Temp Range
Dimensions, Inverter Only
Dimensions, Shipping
Mounting
Indoor, ventilated, steel chassis with powdercoat finish
32°F to 104°F (0°C to +40°C) (output will meet specified tolerances)
-40°F to 140°F (-40°C to +60°C) (output may not meet specified tolerances)
15" (38 cm) high, 22.5" (57 cm) wide, 9" (23 cm) deep (when wall mounted)
20.5" (52 cm), 27" (69 cm), 15.5" (40 cm)
Wall or Shelf Mount
Weight - Inverter Only
Weight - Shipping
90 lbs (42 kg)
96 lbs (44 kg)
105 lbs (48 kg)
111 lbs (50 kg)
105 lbs
111 lbs
105 lbs
111 lbs
105 lbs
111 lbs
136 lbs (63 kg)
143 lbs (65 kg)
136 lbs
143 lbs.
Other voltage/frequency for export are as follows:
SW3024J = 105VAC/50 HZ    SW4024K = 105VAC/60 HZ    SW4024W = 220VAC/60HZ    (two wire output only).
(specifications may change without notice)
Options:  Remote control panel (SWRC), stacking interface cable (SWI), conduit box for code approved DC input battery cables (SWCB).
*********
If you can't find what you are looking for on this page, you are welcome to
SEARCH OUR SITE  

Or Go To Our
Quick Link Site Map